Difference between revisions of "Manuals/calci/CALCITOCHECK"
Jump to navigation
Jump to search
| Line 28: | Line 28: | ||
| − | 4)'''HOUR''','''MINUTE'','SECOND''' function with serial numbers of time as input. | + | 4)'''HOUR''','''MINUTE''','''SECOND''' function with serial numbers of time as input. |
TIMEVALUE("3:30") gives 0.1458333333284827 (which is correct) | TIMEVALUE("3:30") gives 0.1458333333284827 (which is correct) | ||
Revision as of 06:22, 17 December 2013
1) ROWS function
- The function displays #NULL error with arguments as array values.
e.g. ROWS({1,2;3,4;5,6})
Expected result: 3
Observed result: #NULL
2)PRODUCT function
- If the cells in calci have numerical as well as text and empty cells, PRODUCT function assigns '0' to text and empty cells (instead they should be ignored).
e.g. PRODUCT(A1:A5) returns '0' where A1=2,A2=4,A3=TEXT,A4= ,A5=1
Expected result: 8
Observed result: 0
- Function works correctly with logical values. i.e. assigns TRUE=1, FALSE=0
3)OR function
- If the cells in calci have numerical as well as text and empty cells, OR function assigns '0'(FALSE) to text and empty cells (instead they should be ignored).
e.g. OR(TEXT, ) returns FALSE
Expected result: #NULL
Observed result: FALSE
4)HOUR,MINUTE,SECOND function with serial numbers of time as input.
TIMEVALUE("3:30") gives 0.1458333333284827 (which is correct)
If the above serial number is used as input to HOUR, MINUTE and SECOND functions, following are the observations :
- HOUR(0.1458333333284827) displays '19' (Expected Output: '3')
- MINUTE(0.1458333333284827) displays '0' (Expected Output: '30')
- SECOND(0.1458333333284827) displays '0' (correct. But displays '0' for other serial numbers too)
The output is same(i.e. 19,0,0) for any other serial numbers (e.g 0.9479166666642413 for "10:45 PM").